Site Navigation
HOME
VIEW CART
Send Message
Asahi Solder
60Sn 40Pb Solder Wire
Lead-free Solder Bar
Lead-free Solder Wire
DTI Hand Tools
Tweezers
Cutters
Pliers
Electrolube
Air Dusters
Antistatic Products
Aqueous Cleaners
Assembly Products
Conformal Coatings
Oil Lubricants
Service Chemicals
Solvent Cleaners
Thermal Protection
Formit
Component Forming
Hakko
Soldering Equipment
Desoldering Equipment
SMD Rework Tools
Solder Pots
Hand Tools
808 Desoldering Tool
Tips for 936M Irons
936 Base Station Spares
936 Handpiece Spares
Flat Pack removal tips
942 Replacement Parts
950 Hot Tweezers
Cutters and Pliers
Desoldering Spares
Hot Air Nozzles
Kinsten
Making PCBs
Printed Circuit Board
Chemicals & Artwork
Etch Tanks & UV Box
Bench Drill & Drill Bits
Light Emitting Diodes
Super-bright White LED
MeanWell SMPS
Single Output
Dual Output
Triple Output
Quad Output
Chargers
DC-DC converters
DIN Rail Accessories
Switch-mode Manual
Module
Diode Arrays
EMI Filters
Data transceiver
Tx & Rx units
White LEDs
Motech Test Equipment
200kHz Bench LCR Meter
100kHz LCR Meter
Multicore
Solder Wire
Quick-Mark
Label Making
Imaging Film
Base Sheet
Clearance
DC-DC Converters
Multicore Solder Wire
Switches
TERMS
 23 Oct 2008
Superceeded DC-DC converters at bargain prices. Limited stock.
17 Oct 2008
Mean Well hot swap-able 1U low profile 19" rack mounting power system.
14 Oct 2008
Mean Well SCW12 single output PCB mount DC-DC converter.
14 Oct 2008
Mean Well DCW12 dual output PCB mount DC-DC converter
12 Oct 2008
Mean Well SCW08 single output PCB mount DC-DC converter.
 |
|
MT-1010 Power Analyzer
(prices and ordering at the bottom of this page)
 |
Available Parameters
Harmonic Analysis
- up to 40th harmonic
- total harmonic distortion (% THD)
- % fundamental and degree for 1st to 40th harmonic
- RMS value
Power Analysis
- total energy consumption (KWH)
- apparent power (KVA)
- real power (KW)
- reactive power (KVAR)
- true power factor
- displacement angle
Voltage & Current
- frequency
- true RMS
- peak to peak, peak
- crest factor
|
Additional Features
- Inrush current & voltage measurements
- 14 bit resolution with 1W, 1mW and 1mA
- 0.2% basic accuracy
- Accepts inputs directly from Load Adaptor or shunts, CT's & VT's
- Standard infrared interface (RS-232C)
(requires IrDa interface to PC)
- AC, DC, AC+DC coupling for power, voltage and current measurements
- Autorange measurement
|
Applications
- Measuring energy consumption of electrical appliances
- Measurement of maximum & minimum energy demand
- Harmonic analysis of power factor capacitors, variable speed motor drives and solid-state lighting ballasts
- Efficiency measurements
- Measurement of inrush current at switch on
- Determining power factor and PF correction requirements
|
|
Nowadays, many household appliances and similar electrical equipment draw current from power supply system in a very non-linear manner and therefore, inevitable introduce disturbances especially harmonics of supply frequencies into the power system to which they are connected.
However, such equipment should not adversely affect the characteristics of the power supply system, the supply voltage, or the performance of any other equipment connected to the power supply system.
Given that electronic devices connected to supply systems increasing, the control of harmonic emissions is an obvious requirement.
Electrical engineers need not only a tester that would be able to measure, voltage, current and power but a power analyzer that can optimize the harmonic analysis as well. The MT1010 is a handheld Power Analyzer designed with powerful DSP techniques, to provide precise performance of power harmonic analysis to meet the professional needs.
The need to quickly and same time accurately analyze your specific power problems and identify the problems sources is what prompted Motech Industries to introduce this new class of instruments. |
|
Direct Measurement Inputs |
 |
Standard load adapter MT10A is designed to use along with MT1010 for direct measuring input current and voltage during running operations, without interrupting the current path. With this option, users can easily and safely handle the measurement of input current and voltage simultaneously. |
|
Low Current Measurement |
 |
An optional load Adapter MT11A can be used with MT1010 for the measurement of low current for appliances such as Cell-Phone Charger, AC-to-DC Adapter ,UPS ,and so on.
With the load Adapter, the MT1010 can measure the low current as minimal as mA level. Thus, makes it a very useful instrument applicable to variety of fields. (The LCD display readings must be converted into 3 decimal point to get the actual value of the measurement ). |
|
Annuciated Display |
 |
Annuciators on the custom LCD display makes it easy for the operator to understand the reading shown by the MT1010. |
|
Standard Accessories |
 |
1: MT10A Load Adaptor
2: MT10C AC current clamp
3: Test leads ZTP-101MT-1
4: Test leads ZTP-101MT-3
5: Test leads ZTP-101MT-4
6: Clamp-type clips XTB-1010B&R
7: AA-size rechargeable battery
8: Carry case ZCC-200MT-1
DC 6V power adaptor (9) not supplied due to supply variations worldwide.
Other items are optional at additional cost. |
Specifications
Frequency Measurements:
|
| Range (fundamental) |
dc, ac (10 ~ 100 Hz) |
| Accuracy |
± (0.1% + 2%) |
| Bandwidth (harmonic) |
dc, ac (10 Hz ~ 4 kHz) |
True rms Voltage Measurements:
|
| Input range |
2.5V to 900Vrms (ac + dc)
± 5.0V to 1400V (peak) |
| Basic accuracy - dc or rms (ac + dc) |
± (0.2% + 2 digits) |
| Crest factor |
1.00 ~ 5.00 |
| Accuracy |
± (2% + 5 digits) |
True rms Current Measurements:
|
Direct Current Input
|
| Input range |
250 mA to 30 Arms (ac + dc)
± 500mA to ± 50A (peak) |
| Basic accuracy - dc or rms (ac + dc) |
± (0.2% + 5 digits) |
| Crest factor |
1.00 ~ 5.00 |
| Accuracy |
± (2% + 5 digits) |
Isolated Current Input (1 mVrms / Arms)
|
| Input range |
10.0mVrms (A) to 1400 mVrms(A) (ac + dc)
± 20.0mV to ± 2200mV (peak) |
| Basic accuracy - dc or rms (ac + dc) |
± (0.2% + 2 digits) + probe specs |
| Crest factor |
1.00 ~ 5.00 |
| Accuracy |
± (2% + 5 digits) |
Inrush Measurements
|
Voltage input
|
| Input ranges |
1400V, 640.0V, 160.0V, 40.00V, 10.00V, 2.500V |
| Sampling interval |
12.5µs |
| Samplings |
16000 |
| Trig level |
>1/3 Full range |
Direct Current Input
|
| Input ranges |
90.00A, 76.80A, 19.20A, 4.800A, 1.200A, 0.300A |
| Sampling interval |
12.5µS |
| Samplings |
16000 |
| Trig level |
>1/3 Full range |
Isolated Current Input (1mV / A)
|
| Input ranges |
2200mV, 1000mV, 250.0mV, 62.5mV, 15.6mV, 3.9mV |
| Sampling interval |
12.5µS |
| Samplings |
16000 |
| Trig level |
>1/3 Full range |
Power Measurements
|
Direct Current Input
|
| Range |
0.001kVA to 27.00 kVA |
| Accuracy |
± (0.5% + 10 digits) |
| PF |
+1.00 to -1.00 (+ = leading PF, - = lagging PF) |
| Accuracy |
± (2% + 3 digits) |
| Deg ( θv - θI ) |
+180 to -180 degree |
| Accuracy |
± (2% + 5 digits) |
Isolated Current Input (1mV / A)
|
| Range |
0.025kVA to 1260 kVA |
| Accuracy |
± (0.5% + 10 digits) |
| PF |
+1.00 to -1.00 (+ = leading PF, - = lagging PF) |
| Accuracy |
± (2% + 3 digits) + probe specs |
| Deg ( θv - θI ) |
+180 to -180 degree |
| Accuracy |
± (2% + 5 digits) |
Harmonics Measurements
|
Voltage Input
|
| Range |
DC and fundamental to 40th harmonic |
| Max harmonic |
4kHz |
| Accuracy - fundamental |
± (0.2% + 4 digits) |
| Accuracy - harmonics |
± (2% + 4 digits) |
| % THD |
± (3% + 0.03 x reading) |
| Deg ( θ FUND - θ HARM ) |
+180 to -180 degree |
| Accuracy |
2nd ± (1 degree) ~ 40th ± (20.0 degree) |
Direct Current Input
|
| Range |
DC and fundamental to 40th harmonic |
| Max harmonic |
4kHz |
| Accuracy - fundamental |
± (0.2% + 4 digits) |
| Accuracy - harmonics |
± (4% + 4 digits) |
| % THD |
± (4% + 0.03 x reading) |
| Deg ( θ FUND - θ HARM ) |
+180 to -180 degree |
| Accuracy |
2nd ± (1 degree) ~ 40th ± (20.0 degree) |
Isolated Current Input
|
| Range |
DC and fundamental to 40th harmonic |
| Max harmonic |
4kHz |
| Accuracy - fundamental |
± (0.2% + 4 digits) + probe specs |
| Accuracy - harmonics |
± (2% + 4 digits) + probe specs |
| % THD |
± (3% + 0.03 x reading) + probe specs |
| Deg ( θ FUND - θ HARM ) |
+180 to -180 degree |
| Accuracy |
2nd ± (1 degree) ~ 40th ± (20.0 degree) + probe specs |
General
|
| Temperature (operating) |
0°C to 40°C |
| Temperature (storage) |
-20°C to 70°C |
| Relative humidity |
up to 85% |
| Battery type |
Ni-Mh or Alkaline (2 x AA size) |
| Battery charge |
Constant current 160mA approximately |
| Battery operating time |
2.5 hours (typical) |
| Low power warning |
< 2.2V |
| Dimensions |
174 x 86 x 48mm (L x W x H) |
| Weight |
470g |
| Specifications subject to change without notice |
PRICES
MT-1010 Power Analyzer
| Order Code |
ex GST |
|
| MT-1010 Power Analyzer |
A$ 1470.00 |
|
| MT-11A Low current load adapter |
A$ 135.00 |
|
Prices do not include GST. 10% GST applies to goods delivered in Australia.
Australian GST is not paid on shipments despatched to an international destination.
Prices are in Australian Dollars and subject to change without notice.
Sales are subject to Computronics General Terms and Conditions of Sale
E.& O.E.
Due to continuing product improvement efforts, specifications and appearance are subject to change without notice.
All mains powered equipment supplied by Computronics operates from 240Vac, 50Hz supply unless otherwise specified.
To place an order, select the order quantity and click the ADD button.
Add items from other pages - if required.
When all items have been added, click a View Cart link to edit your order and continue to the secure order page.
If ADD buttons are not visible, then Java might not be installed or enabled.
Java can be downloaded from the GET JAVA site.
Java and SSL must be enabled for the shopping cart to operate.
|